The COpilotTM atmosphere sensing device has been designed and engineered to meet the highest safety standards of today’s gas industry, where reliable protection is required not only on flueless gas heaters, but open and closed flue space heating appliances.

The British made COpilotTM has a precise, reliable and effective response, cutting off the gas supply under vitiated conditions in line with current European and International criteria.

 

COpilotTM is of robust construction: consisting of the burner, thermocouple and electrode; securely mounted onto a steel bracket for easy installation onto the chassis of the appliance

 

 

TECHNICAL DATA

      Gas rate:      -  200 Watts on Natural or LP gases.

 

      Gas connections:  -  M10 internal compression nut for 4 mm diameter tube

 

      Attachment    -  2 x 4 mm holes (one slotted) - minimum distance between centres—22 mm.

 

      Thermocouple     -  320,450 & 1000 mm length with M8 or M9 connection.